Skip to content
-
Subscribe to our newsletter & never miss our best posts. Subscribe Now!
Control Tech Daily Control Tech Daily
Control Tech Daily Control Tech Daily
  • Home
  • Brand
  • Guide
  • Industry
  • Scheme
  • Science
  • Share
  • Case
  • Home
  • Brand
  • Guide
  • Industry
  • Scheme
  • Science
  • Share
  • Case
Close

Search

  • ABB
  • AI-Tek
  • Allen-Bradley
  • Bently Nevada
  • Emerson
  • Fanuc
  • Flexem
  • GE
  • HIMA
  • Lenze
  • Mitsubishi
  • Schneider Electric
  • Siemens
  • TR Electronic
  • Vibro-Meter
  • Woodward
Subscribe
Control Tech Daily Control Tech Daily
Control Tech Daily Control Tech Daily
  • Home
  • Brand
  • Guide
  • Industry
  • Scheme
  • Science
  • Share
  • Case
  • Home
  • Brand
  • Guide
  • Industry
  • Scheme
  • Science
  • Share
  • Case
Close

Search

  • ABB
  • AI-Tek
  • Allen-Bradley
  • Bently Nevada
  • Emerson
  • Fanuc
  • Flexem
  • GE
  • HIMA
  • Lenze
  • Mitsubishi
  • Schneider Electric
  • Siemens
  • TR Electronic
  • Vibro-Meter
  • Woodward
Subscribe
Bently NevadaBrandCase

Bently Nevada 9200-03-05-05-00 | Two-Wire Velocity Seismoprobe Transducer

By wayne
June 6, 2026 2 Min Read
0

Product Procurement & Buyer Guide

The 9200-03-05-05-00 is a two-wire velocity seismoprobe transducer from Bently Nevada. This model comes with a 1/2‑in 20 UNF‑3A stud mounting base and a terminal block top connector. Engineers select this variant for directly threaded installations on rotating machinery casings.

You gain a sensitivity of 20 mV/mm/s with ±5% accuracy. The transducer operates at a minimum frequency of 4.5 Hz (270 cpm) and mounts at a 90° angle. This configuration supports typical vibration monitoring for pumps, fans, and compressors.

The unit withstands temperatures from -29°C to +121°C. Its anodized aluminum case offers dust and moisture resistance up to 95% relative humidity. You can order it without additional agency approvals, reducing lead time for standard industrial applications.

Procurement teams value the 12‑month factory warranty and original packaging. The part number 9200-03-05-05-00 ensures correct specification matching. Ordering this exact variant eliminates compatibility risks with existing Bently Nevada monitoring systems.

9200-03-05-05-00 Industrial Automation Spare Parts

Step-by-Step Installation Guide

Begin by cleaning the mounting surface. The 1/2‑in 20 UNF‑3A stud threads directly into a tapped hole on the machine casing. Tighten to the manufacturer’s recommended torque without over‑compressing the neoprene gasket.

Connect the terminal block top mount. Use a 10 kΩ calibration load across terminals “A” and “B”. The output signal appears between these two pins. Ensure the cable is shielded and routed away from high‑voltage sources.

Orient the transducer at exactly 90° ±2.5° relative to the measurement axis. This orientation matches the factory calibration angle. A deviation beyond this tolerance will reduce sensitivity accuracy.

Apply power through a two‑wire loop. The transducer draws its operating current from the same pair that carries the vibration signal. Confirm the monitoring module supplies at least 10 mA to the loop.

Verify the velocity range of 25 mm/s at 100 Hz with a 10 kΩ load. Use a handheld vibration calibrator to check output. The locked coil inductance of 125 mH ensures stable performance in noisy environments.

Logistics & Standard Packaging Details

    • One Bently Nevada 9200-03-05-05-00 transducer
    • Neoprene gasket pre‑installed
    • Terminal block connector top mount
    • Original factory packing with anti‑static foam

9200-03-05-05-00 Industrial Automation Spare Parts

  • Calibration certificate traceable to factory standards

Express delivery is available via FedEx, UPS, and DHL. Orders placed before 14:00 EST ship the same business day. Expedited air freight is also an option for critical outages.

Tags:

9200-03-05-05-00Bently Nevada
Author

wayne

Follow Me
Other Articles
Previous

Bently Nevada 9200-09-01-01-00 Two-Wire Velocity Seismoprobe

Next

Flexem FR-D0808N Digital Mixed I/O Module – Reliable 8-Point NPN Output

No Comment! Be the first one.

    Leave a Reply Cancel reply

    Your email address will not be published. Required fields are marked *

    This site uses Akismet to reduce spam. Learn how your comment data is processed.

    Search

    Brand

    ABB
    GE
    Allen-Bradley
    Bently Nevada
    Yokogawa Electric
    Honeywell
    Vibro-Meter
    Woodward
    Siemens
    TR Electronic
    Emerson
    Fanuc
    Flexem
    AI-Tek
    HIMA
    Lenze
    Mitsubishi
    Schneider Electric

    Recent articles

    • Bently Nevada 165855-15-CN Cylinder Pressure Transducer: Key Insights July 17, 2026
    • Bently Nevada 107770-02-01 Velocity Transducer Housing for Hazardous Areas July 17, 2026
    • Bently Nevada 107770-01-02 Velocity Transducer Housing for Hazardous Areas July 17, 2026
    • Bently Nevada 107770-01-03 Velocity Transducer Housing for Hazardous Areas July 17, 2026
    • Allen-Bradley 2094-BC02-M02-M Integrated Axis Power Module News July 17, 2026
    • Bently Nevada 2300/20-02 Vibration Monitor: New Product News July 17, 2026

    About US

    We are a professional information hub for automation equipment, providing industry news, supplier updates, product evaluations, shopping guides, usage guidance, and more.

    Contact Us

    Addr.:
    Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

    Email:[email protected]

    Tel:+86 180 3000 5825

     

     

     

    About US

    Control Tech Daily is a professional information hub for automation equipment, providing industry news, supplier updates, product evaluations, shopping guides, usage guidance, and more.

    Links

    • SpareTech PLC
    • Ubest Automation

    Tags:

    2097-V34PR5 5464-643 5464-843 ABB AI-Tek Allen-Bradley Bently Nevada DeltaV Emerson Fanuc Flexem Flexem HMI Flexem PLC FR-ECAT GE HIMA Honeywell ICS Triplex Lenze Schneider Schneider Electric Siemens T8231 T8311 T8312 T8449 T8850 T8891 T9402 T9432 T9451 TR Electronic Triconex Woodward Yokogawa Electric

    Recent articles

    • Bently Nevada 165855-15-CN Cylinder Pressure Transducer: Key Insights July 17, 2026
    • Bently Nevada 107770-02-01 Velocity Transducer Housing for Hazardous Areas July 17, 2026
    • Bently Nevada 107770-01-02 Velocity Transducer Housing for Hazardous Areas July 17, 2026
    • Bently Nevada 107770-01-03 Velocity Transducer Housing for Hazardous Areas July 17, 2026
    • Allen-Bradley 2094-BC02-M02-M Integrated Axis Power Module News July 17, 2026
    • Bently Nevada 2300/20-02 Vibration Monitor: New Product News July 17, 2026
    • Bently Nevada 2300/20-00 Vibration Monitor: Key Specs & Applications July 17, 2026
    • Bently Nevada 2300/20_KIT-001-00: Science of Condition Monitoring July 16, 2026
    • Bently Nevada 2300/25-00 Monitor with SPA Outputs Scheme July 16, 2026
    • Bently Nevada 2300/20_KIT-001-02-00 Condition Monitoring System Guide July 16, 2026

    Contact Us

    Addr.:
    Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

    Email:[email protected]

    Tel:+86 180 3000 5825

    Copyright 2026 — Control Tech Daily. All rights reserved.